Result
On the Hyper Terminal interface, press Enter, and the system prompts you to input the user
name. Input the user name and the password for user registration (by default, the super user name
is root and the password is admin), and wait until the CLI prompt character is displayed.
NOTE
If the login fails, click
return to step 1 to check the parameter settings and the physical connections, and then try again.
Follow-up Procedure
l
l

1.3.5.2 Login Through Telnet (Outband Management)

This topic describes how to log in to the MA5600T/MA5603T/MA5608T using the local
maintenance Ethernet port (outband management port) in the telnet mode to maintain and
manage the MA5600T/MA5603T/MA5608T. You are advised to use SSH mode.
Prerequisites
Engineers are logged in to the MA5600T/MA5603T/MA5608T by using the local serial port or
the ETH port.
NOTE
Issue 01 (2014-04-30)
NOTE
When you paste a text to the HyperTerminal, the character delay controls the character transmit speed,
and the line delay controls the interval of transmitting every line. If a delay is very short, loss of
characters occurs. When the pasted text is displayed abnormally, modify the delay.
To improve the system security, please modify your password after first login. You can run the terminal
user password command to modify your password.
and then click
You can run the idle-timeout command to set the terminal timeout time. if you do not input
commands within the specified timeout time, the system disconnects the terminal. By
default, the terminal timeout time is set to 5 minutes. If you do not run any commands
within 5 minutes, the system disconnects with the terminal. To perform any operation, you
must have to log in to the system again.
In the commissioning procedure, you must use the command, It is recommended that you
know well the command modes
Figure 1-12
Login
enable
User mode
huawei>
quit
disable
The default IP address of the maintenance Ethernet port (ETH port on the control board) is 10.11.104.2,
and the subnet mask is 255.255.255.0.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
on the operation interface. If the login still fails,
first.Figure 1-12
shows how to switch command modes.
config
Global config mode
Privilege mode
huawei#
huawei(config)#
quit
1 Commissioning
Interface/config mode
interface
huawei(config-if-...)
quit