・Specifying condition1 / Specifying condition 1 and 2
Specify 1 or 2 conditions and a signal value. The set value is applied when the set conditions are
satisfied.
(2) Signal type
Specify a Signal type.
Select from [PIO](default), [CC-Link(Link Relay)] and [CC-Link(Link Register)].
The following items differ according to [Simulation operation] and [Signal type].
(3) Source / Destination / Reference side / Setting side
Select a source from a robot or a device of GX Simlator2.
Select from [Project ID: Project name] (as many items as there are projects), [GX Simulator2 A], [GX
Simulator2 B], [GX Simulator2 C] and [GX Simulator2 D].
GX Simulator2 is named "A", "B", "C", "D" in the order of starting.
Figure 19-9 Items of Source / Destination / Reference side / Setting side
(4) Device
When [Source] / [Destination] / [Reference side] / [Setting side] is GX Simulator2, select a device used in
simulation. When it is robot, a device is fixed.
[Signal Type]
[PIO]
[CC-Link(Link relay)]
[CC-Link(Link register)]
19-443
Figure 19-8 Specifying condition
Table 19-1 Selectable Devices
[Source]/[Destination]/[Reference side]/[Setting side]
Robot
[Bit device]
[Word device]
GX Simulator2
[B(Bit device)]
[D(Word device)]
[L(Bit device)]
[M(Bit device)]
[R(Word device)]
[W(Word device)]
[Y(Bit device)]