Io Unit Monitor - Mitsubishi Electric MELFA CR750 Series User Manual

Hide thumbs Also See for MELFA CR750 Series:
Table of Contents

Advertisement

12.2.5. IO unit monitor

You can monitor XY device variables of IO unit.
From the project tree, double-click the target project [Online] -> [Monitor] -> [Signal Monitor] -> [IO unit].
The status of input signals are displayed on the upper table, and the status of output signals are displayed
on the lower table.
The signal values can display a 16-bit integer with a mark, or 32-bit integer with a mark by the decimal
number or the hexadecimal number.
The signasl to display can set up the continuous range freely with [Monitor setting].
This function can be used with Version R3 or later of CR750-Q/CRnQ-700 robot controllers and Version
2.10L or later of this software.
12.2.5.1. Monitor setting
Click the [Monitor setting] button. The setting screen of PLC IO unit monitor is displayed.
Set the starting number of each device and set the number of lines to display. And, set the data size in
display singles and the display method.
After setting, click the [OK] button.
12-245
Figure 12-33 IO unit monitor
Figure 12-34 IO unit seting screen