Mitsubishi Electric MELFA CR750 Series User Manual page 320

Hide thumbs Also See for MELFA CR750 Series:
Table of Contents

Advertisement

All Files
Program
Parameter Files
System Program
Change Robot Origin
Data
Change Robot Arm
Serial Number
Restore the file
manager's data
Restore Operating
Information
15-320
:
Transfers all files (except BKUP.SYS and MECHA.SYS) in the designated
folder to the robot controller after all information in the robot controller is cleared
(initialized).
:
Transfers the robot program file in the designated folder to the robot controller.
:
Transfers the parameter file in the designated folder to the robot controller.
:
Transfers the system base program file in the designated folder to the robot
controller.
:
This is backup information and it only valid when All or Parameter files is
selected. Operations for when this checkbox is checked and when it is not are
as in "Table 15-1 ".
:
If you check this checkbox, the robot main unit serial number is also rewritten.
:
If you check this checkbox, the data treated with file manager (refer chapter
13.8) is also restored. This function can be used with Version 3.00A or later of
this software.
:
If you check this checkbox, the operating information (power on time, operation
time, servo on time, and battery remaining time) of the robot controller is
transferred. This function can be used with Version 3.60N or later of this
software.
15-320

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melfa cr700 seriesMelfa cr500 seriesMelfa rt toolbox2Melfa rt toolbox2 min

Table of Contents