Mitsubishi Electric MELFA CR750 Series User Manual page 332

Hide thumbs Also See for MELFA CR750 Series:
Table of Contents

Advertisement

<3> Button type
<4> Movement setting
Example of setting the movement of button
For example:
The button that output signal number 20 to High when input signal number 20 is High.
(1) A default value of "Button operating condition"
window is shown in a right picture.
(2) Set the condition of operation.
Click <d>, and select the signal type.
When things except "Unconditionally" are
selected, the input area of signal number and
the combo box to select the state are displayed.
Now, select "input signal".
16-332
: The kind of the button can be set.
Alternate
When the button is clicked once, the button keeps ON state. And
when the button is clicked again, it returns to OFF state.
The signal output is kept too.
Momentary
The button keeps ON state while it is being pushed.
: The condition and the signal output operation when the button ON can be set.
The condition can be selected as follows. Please set the signal number etc. when
you make the signal state the condition. When the button is ON or OFF, the
condition is judged.
-
Unconditionally
-
State of the specified Input signal
-
State of the specified output signal
The signal output operation can be selected as follows. Please set the signal
number etc. when you output the signal.
-
Done nothing
-
Output the specified output signal
Operation setting can be set up to two.
Two operation settings operate individually by using each condition.
Moreover, when High and Low are set to output to the same signal, and both
conditions become true, the Condition2 is given priority.
If the operation is set signal output, when the button is OFF, the signal is output in
the state opposite High/Low state at the time of ON.
<d>
16-332