Security function of the robot controller (Password Setup)

It is possible to forbid to accessing the robot programs, parameters and files in the robot controller.
The security function can be achieved by setting the password to the robot controller. This function can be
used with Version 2.00A or later of this software. And the software version of the robot controller which can be
used is as follows.
CR750-D/CRnD-700 series
CR750-Q/CRnQ-700 series
CRn-500 series
The function that the password can be set is as follows. It is possible to setup the password to access of the
program, parameters, and files individually. The factory default setting of "Password Setup" are off.
Type
・ Writing the programs.
Program
・ Reading the programs.
・ Copying the programs.
・ Renaming the programs.
・ Deleting the programs.
・ Writing the position data for SQ Direct.
・ Reading the position data for SQ Direct.
・ Deletion of all robot programs.
・ File Manager
・ Writing the parameters.
Parameter
・ Position repair function.
・ Restore the origin data.
・ Restoring the program information
・ Backup
File
・ Restore
・ Position repair function
Use the registration, change, and the deletion of the password while connected to the robot controller. From
the project tree, click on the menu bar [Online] → [Password Setup], or double click the target project [Online]
→ [Maintenance] → [Password Setup].
13-297
Table 13-15 Compliant version of this function and controller
Robot Controller
Table 13-16 Function that access is limited.
Limited functions
Software version of robot controller
S3
R3
not use
It is not possible to delete the file, or
rename the file.
It is possible to read the parameters
from the robot controller.
It is not possible to write the revision
parameter created by "Position repair
function" in the robot controller.
Program
restored though < Write the task slot#
> error is displayed when program
information is restored before this
software version 1.8 or earlier.
Remarks
information
is
correctly