Example of setting lamp ON/OFF
For example:
Lamp that is turned on when the input signal number 20 is High, and is turned off when the input signal
number 20 is Low.
(1) A default value of "The Lamp on/off
condition" window is shown in a right
picture.
(2) Set "On condition".
Click <h>, and Select the signal type.
Now, select "input signal".
(3) Input "20" to signal number (<i>).
(4) Select "High" (<k>), as a state of
signal to light the lamp.
(5) Similarly, set the condition for turning
off the lamp, and click [OK] button (<l>).