Cisco SR2016T-NA Reference Manual page 367

Reference guide
Hide thumbs Also See for SR2016T-NA:
Table of Contents

Advertisement

Chapter 2
Cisco CMTS Configuration Commands
cable upstream timing-adjust
To enable upstream timing adjustment for a specified cable interface, use the cable upstream timing-
adjust command in cable interface configuration mode. To return to the default values, use the no form
of this command.
Syntax Description
n
continue sec
threshold sec
Defaults
2 seconds for continue and 1 second for threshold
Command Modes
Interface configuration (cable interface only)
Command History
Release
11.3 NA
12.0(12)SC
12.1(3)T
12.1(3a)EC
Usage Guidelines
To verify whether or not upstream timing adjustment is configured and activated, enter the show
running-config command and look for the cable interface configuration information. If upstream timing
adjustment is enabled, either or both of the continue and threshold timing adjustment entries are
displayed in the show running-config output. If both the continue and threshold upstream timing
adjustments are disabled, no timing adjustment entry is displayed in the show running-config output.
If you are having trouble, make sure that the cable connections are not loose or disconnected; the cable
interface line card is firmly seated in its chassis slot; the captive installation screws are tight; and you
have entered the correct slot and port numbers.
The cable timing-adjust command is applicable only on Cisco IOS Release 12.0(12)SC and Cisco IOS
Note
Release 12.1(3)T. It is deprecated and removed on Cisco IOS Release 12.1(3a)EC, 12.1(4)CX, and later
releases.
OL-1581-08
cable upstream n timing-adjust {continue sec | threshold sec}
no cable upstream n timing-adjust {continue sec | threshold sec}
Modification
This command was introduced.
This command was supported on the 12.0 SC release.
This command was supported on the 12.1 T release.
This command was removed and no longer supported on the 12.1 EC and
later releases (including those releases, such as 12.1 CX, that are based on
the 12.1 EC train).
Specifies the upstream port number. Valid values start with 0 for the
first upstream port on the cable interface line card.
Sets the minimum timing adjustment that sets continue ranging status
in seconds. The range for sec is 2 to 64 seconds. Default value is
2 seconds.
Sets the timing adjustment threshold in seconds. Valid threshold value
is 1 to 32 seconds. Default is 1 second.
Cisco Broadband Cable Command Reference Guide
cable upstream timing-adjust
2-355

Advertisement

Table of Contents
loading

This manual is also suitable for:

Broadband cable