cable spectrum-group (global configuration)
If both an Cisco uBR-MC16E cable interface line card and a Cisco uBR-MC16C or a Cisco uBR-
Note
MC16S cable interface line card are present in the chassis, a spectrum group in the 42-MHz to 65-MHz
range should not be assigned.
Tip
Cisco cable interface line cards always program the upstream's center frequency in 16 KHz increments,
and this is the frequency displayed by the show controller cable upstream command. For example, if
you use the
cable upstream frequency
command to specify a center frequency of 27 MHz (cable
upstream x frequency 27000000), the actual center frequency will be 27.008 MHz, which is the next
highest 16 KHz boundary.
You must repeat this command for each frequency or power level that you want to add to a spectrum
group's list of valid values.
After you have created one or more spectrum groups for your cable network, you can add characteristics
to them, providing you with more definitive control over frequency usage and frequency hopping.
The cable interface does not operate until you either create and configure a spectrum group or set a fixed
upstream frequency. See the
cable upstream channel-width
command.
Examples
The following example shows how to configure spectrum group 1 with an upstream frequency of
6,500,000 Hz and a default power level of 0 dBmV:
Router(config)# cable spectrum-group 1 frequency 6500000
The following example shows how to add the upstream frequency 7,000,000 Hz to the list of valid
frequencies with a default power level of 0 dBmV for spectrum group 1:
Router(config)# cable spectrum-group 1 frequency 7000000
The following example shows how to configure spectrum group 2 with an upstream frequency
7,500,000 Hz and change the power level to 5 dBmV:
Router(config)# cable spectrum-group 2 frequency 7500000 5
The following example shows how to configure spectrum group 3 with an upstream band of 12,000,000
to 18,000,000 Hz and default power level of 0 dBmV:
Router(config)# cable spectrum-group 3 band 12000000 18000000
The following example shows how to add the upstream band 20,000,000 to 24,000,000 Hz to the list of
valid bands with a change in the power level of 13 dBmV for spectrum group 3:
Router(config)# cable spectrum-group 3 band 20000000 24000000 13
The following example shows how to configure a continuous band between 5,000,004 and
40,000,000 Hz for scheduled spectrum group 4 with a default power level of 0 dBmV. The spectrum
group will be available to the spectrum group starting at 12:00 p.m. local time each Monday:
Router(config)# cable spectrum-group 4 time Monday 12:00:00 band 5000004 40000000
The following example shows how to add the upstream frequency 9,500,000 Hz to the list of valid
frequencies and change the nominal power level to 5 dBmV. The spectrum manager adjusts frequencies
and power levels on this group at 2:00 a.m. local time each day:
Router(config)# cable spectrum-group 3 time 02:00:00 frequency 9500000 5