Chapter 3
Cisco CMTS Show Commands
System restarted at 08:59:44 UTC Wed Jul 21 2004
Running default software
cisco uBR10K CLC (NPE-CLC) processor (revision A) with 196608K/65536K bytes of m
emory.
Processor board ID
R7000 CPU at 262MHz, Implementation 39, Rev 2.1, 256KB L2 Cache
6 slot midplane, Version 1.0
.
.
.
The following is sample output for the downstream connection for slot 3 on port 0 on Cisco CMTS router
from the show controllers cable downstream command:
CMTS01# show controllers cable 3/0 downstream
Cable 3/0 Downstream is up
Frequency not set, Channel Width 6 MHz, 64-QAM, Symbol Rate 5.056941 Msps
FEC ITU-T J.83 Annex A, R/S Interleave I=12, J=17
Table 3-43
Table 3-43 show controllers cable downstream Field Descriptions
Field
Cable
Downstream is up
Frequency
Channel Width
QAM
Symbol Rate
FEC ITU-T
R/S Interleave I/J
For cable interfaces that include an integrated upconverter, the show controllers cable command
includes the frequency and power settings for the integrated upconverter. The following example shows
typical output for the show controllers cable command that includes the information for the integrated
upconverter:
ubr7100# show controllers cable 1/0
Interface Cable1/0
Hardware is IMC11
BCM3210 revision=0x56B2
Cable1/0 Upconverter is Enabled Output is Enabled
Model: 74-2094-01 Serial Number: 0WAV04480010 CLEI Code:
HW Rev:
Downstream Frequency 525.0000 MHz
IF Power 0.3 dBmv
...
OL-1581-08
describes the fields displayed by the show controllers cable downstream command.
Description
Slot number/port number indicating the location of the Cisco cable
interface line card.
Indicates that the RF downstream interface is enabled.
Transmission frequency of the RF downstream. (This information
may not match the current transmission frequency, which is
external on CMTS platforms that use an external upconverter.)
Indicates the width of the RF downstream channel.
Indicates the modulation scheme.
Indicates the transmission rate (in number of symbols per second).
Indicates the Motion Picture Experts Group (MPEG) framing
standard.
Indicates Reed Solomon framing based on ITU S.83-B.
PC2D0107 SW Rev: 007, NVRAM Rev: 006 ECI number 123456
RF Power 51.0 dBmv
CLEI#
Cisco Broadband Cable Command Reference Guide
show controllers cable
3-169