4-PAW DIESEL/HYDRAULICS
18. Remove the absorbent towel.
19. Slide the fan onto the fan adapter (Fig. 1510).
20. Using a 7/16" socket, install 4 bolts and lock wash-
ers securing the fan to the fan adapter. Torque the 4
bolts to 100 ± 10 ft-lbs. (136 ± 14 Nm) (Fig. 1511).
6/2-52
Fig. 1510
DSC-1777a
Fig. 1511
DSC-1782a
21. Install the radiator. Refer to "Radiator Installation" on
page 6/4-97.
22. Start the machine. Allow the air to purge from the
hydraulic system. Check the hydraulic lines and
fittings for leaks.
23. Turn the machine off and remove the key.
24. Check the hydraulic fluid level and add if necessary.
Toro Wheeled CUL Service Manual