M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
#12912
aux_pusht2
Set the time from the completion of the stopper operation to the changeover of the stopper torque in the stop-
per positioning.
---Setting range---
0 to 9999(ms)
#12913
aux_pusht3
Set the time from the completion of the stopper operation to the output of the "automatic set position reached"
(JSTA), "set position reached" (JST) or "near set position" (NEAR) signal in the stopper positioning.
---Setting range---
0 to 9999(ms)
IB-1501279-H
Stopper torque release time
Set position signal output delay time