M800/M80/E80/C80 Series Alarm/Parameter Manual
15 User Parameters
#8974
Simple PLC switch
Select whether to enable ON/OFF of PLC switch without a press of the [Setting valid] menu.
0: Enable ON/OFF of PLC switch after a press of the [Setting valid] menu.
1: Enable ON/OFF of PLC switch without a press of the [Setting valid] menu.
#8975
No. search process
Select how the [XXX No search] menu works on screens including the parameter and tool offset screens.
0: When you press [No search], enter the No. to display and then press [INPUT], the data on the display
is ordered to start from the designated No.
1: When you enter the No. to display and then press [No. search], the data on the display is ordered to start
from the designated No.
#8976
Menu animation OFF
[M8]
Select whether to disable animated graphics of the menus.
0: Enable
1: Disable
[C80]
Not used.
#8977
Multi-$ simul edit
Select whether to open the same named programs of different part systems simultaneously for each editing
area upon a press of Open on Edit screen while Multi-part system program management is enabled.
0: Disable (Not open the programs simultaneously for each editing area)
1: Enable (Open the programs simultaneously for each editing area)
#8979
Touch op noise res
[M8]
Set the noise tolerance of touch operation.
The larger setting value gives the higher noise tolerance, but the operation response becomes dull.
0: Select this when the motions are normal at one and two points in the stable environment of the power
supply.
1 to 4: If the touch detection position is unstable, increase the setting value according to the cursor blur
level.
(Note) Do not execute touch operation for two seconds after changing this parameter.
[C80]
Not used.
IB-1501279-H