M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
(PR)
#1353
MC_ct1
Set a device of an output remote I/O device to control contactor in safety observation.
When set to "0", contactor shutoff output is disabled.
Thus, "Y0" cannot be used as contactor shutoff output device.
---Setting range---
[M8]
0000 to 02FF (HEX)
[C80]
0000 to 01FF (HEX)
(PR)
#1357
mchkt1
Set a period of time until emergency stop is issued when a contactor does not operate even though contactor
shutoff output 1 is output.
If the vertical axis drop prevention function is used, set a value bigger than the vertical axis drop prevention
time (SV048 EMGrt).
When "0" is set, the contactor operation check will be disabled.
---Setting range---
0 to 30000 (ms)
(PR)
#1361
aux_acc
Select the acceleration/deceleration type of auxiliary axis in PLC axis indexing.
0: Acceleration/deceleration with constant time
1: Acceleration/deceleration with a constant angle of inclination
#1365
manualFtype
Select the manual speed command type.
0: Manual speed command
The axis travels at the handle/jog feed rate.
Reverse run is performed for each part system independently of the other ones.
1: Manual speed command 2
In a multi-part system configuration, the axis travels at the handle/jog feed rate multiplied by the ratio of
each part system's program command speeds.
When the block start point is reached in reverse run in any of the part systems, the axes in the other part
systems stop simultaneously.
#1366
skipExTyp
Select the operation when G31 is commanded in more than one part system.
(Note) When set to "1", the skip coordinate position will always be "0" whether G31 is commanded in a single
part system or in one part system of a multi-part system.
Set to "0" when using G31 command for measurement etc.
0: Carry out G31 command in one part system, while the G31 is kept in an interlocked state in the other
systems.
1: Carry out G31 command simultaneously in more than one part system.
Note that the skip coordinate is not read and so the skip coordinate value will be 0.
#1367
G1AccOVRMax
Set the maximum override value to be applied to the cutting feed that is in constant inclination acceleration/
deceleration.
When the setting of this parameter is between 0 and 99, the override value is handled as 100% even though
the specified cutting feed override is over 100%.
---Setting range---
0 to 300(%)
(PR)
#1369
S_Sig1
Set the remote I/O device to input the observation speed change signal 1 during executing the safety obser-
vation function.
When set to "0", there is no observation speed change signal input.
Therefore "X0" cannot be used as safety observation signal device.
---Setting range---
0000 to 02FF (HEX)
IB-1501279-H
Contactor shutoff output 1 device
Contactor operation check allowed time 1
Auxiliary axis acceleration/deceleration type
Manual speed command type
Multi-system simultaneous skip command
Max. override value for cutting feed constant inclination
acc./dec.