M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
#24007+40(n-1)
[M8]
Set the total number of remote stations, local stations, intelligent device stations, standby master station and
reserved stations connected to the master station.
"n" represents the expansion slot No.(n=1 to 3)
---Master station---
Set to either of "1" to "64".
---Local/standby master station---
Set to "0".
---Setting range---
0 to 64 (modules)
#24008+40(n-1)
[M8]
Set the number of retries for when a communication error occurs.
"n" represents the expansion slot No.(n=1 to 3)
---Master station---
Set to either of "1" or "7".
---Local/standby master station---
Set to "0".
---Setting range---
0 to 7 (times)
#24009+40(n-1)
[M8]
Set the total number of remote stations, local stations, intelligent device stations and standby master station
that can be returned to system operation by a single link scan.
"n" represents the expansion slot No.(n=1 to 3)
(Note) Refer to "CC-Link System Master/Local Module User's Manual (SH(NA)-080394E)" for the details of
the functions.
---Master station---
Set to either of "1" or "10".
---Local/standby master station---
Set to "0".
---Setting range---
0 to 10 (modules)
(PR)
#24010+40(n-1)
[M8]
Set the station No. of the standby master station.
"n" represents the expansion slot No.(n=1 to 3)
Set "0" when no standby master station is provided.
---Master station---
Set a value within the setting range.
---Local/standby master station---
Set "0" (fixed) for the local station.
Set "1" (fixed) for the standby station.
---Setting range---
0 to 64
IB-1501279-H
SLn conn modules
SLn num of retries
SLn auto ret mdls
SLn STBY master st
662
Number of connected modules
Number of retries
Number of automatic return modules
Standby master station