M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
(PR)
#13036
SP036 SFNC4
Select the spindle function.
A function is allocated to each bit.
Set this in hexadecimal format.
bit F-8 :
Not used. Set to "0".
bit 7 : mksl Coil selection in spindle synchronization mode
0: Select the coil commanded during synchronization 1: Select high-speed coil
bit 6 : rtt_vgns Real-time tuning I in spindle synchronization mode / speed gain adaptation stop
0: Stop
bit 5 :
Not used. Set to "0".
bit 4 : shgs SHG control in spindle synchronization mode
0: Stop
When using the OMR-FF control, set to "0".
bit 3 :
Not used. Set to "0".
bit 2 : pys Excitation rate selection in spindle synchronization mode
0: Select Excitation rate 1
bit 1 : vgs Speed loop gain set selection in spindle synchronization mode
0: Select Set 1 (SP005,SP006,SP007) 1: Select Set 2 (SP008,SP009,SP010)
bit 0 :
Not used. Set to "0".
#13037
SP037 JL
Set the motor axis conversion total load inertia including motor itself in proportion to the motor inertia.
SV037(JL)=(Jm+Jl)/Jm×100
Jm: Motor inertia
Jl: Motor axis conversion load inertia
---Setting range---
0 to 5000 (%)
#13038
SP038 FHz1
Set the vibration frequency to suppress when machine vibration occurs.
(Enabled at 50 or more.)
When not using, set to "0".
Related parameters: SP034/bit3-1
---Setting range---
0 to 5000 (Hz)
#13039
SP039 LMCD
Set this parameter when the lost motion compensation type2 timing does not match.
Adjust by increasing the value by 10 at a time.
---Setting range---
0 to 2000 (ms)
1: Start
1: Start
1: Select Excitation rate 2
Spindle function 4
vgs
pys
shgs
rtt_vgns
mksl
Load inertia scale
Notch filter frequency 1
Lost motion compensation timing
597