M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
#24011+40(n-1)
[M8]
Set the data link status for when the master station failure occurs.
"n" represents the expansion slot No.(n=1 to 3)
0: Fixed to stop
(Note) Refer to "CC-Link System Master/Local Module User's Manual (SH(NA)-080394E)" for the details of
the functions.
---Master station---
Set to "0" (fixed).
---Local/standby master station---
Set to "0".
#24012+40(n-1)
[M8]
Select whether to synchronize the link scan with one ladder scan.
"n" represents the expansion slot No.(n=1 to 3)
0: Fixed to synchronize
---Master station---
Set to "0" (fixed).
---Local/standby master station---
Set to "0".
#24013+40(n-1)
[M8]
Set the delay time.
"n" represents the expansion slot No.(n=1 to 3)
0: (Fixed value)
---Master station---
Set to "0" (fixed).
---Local/standby master station---
Set to "0".
#24014+40(n-1)
[M8]
Set the refresh device name of the remote input (RX) to be automatically refreshed.
(Example) X
"n" represents the expansion slot No.(n=1 to 3)
Set "0" when no setting is required.
---Master station---
Set a value within the setting range.
---Local/standby master station---
Set a value within the setting range.
---Setting range---
0,X,M,L,B,D,W,R
SLn ope at NC down
SLn scan mode
SLn delay time
SLn RX dev name
663
Operation at NC down
Scan mode
Delay time
Remote input (RX) refresh device name