1 Operation Errors (M)
M01

Spindle sync cancel error

Details
Spindle synchronization cancel command has been issued during rotation of C axis under spindle sync C
axis control.
G113 (without the address H or D) has been issued during the spindle synchronization for two or more
sync sets.
Remedy
This operation error is cancelled when C axis stops. Issue a spindle sync cancel command after C axis
has stopped.
Use G113D or G113H to cancel the spindle synchronization.
M01

GB SP sync:Cancel sgnl illegal

Details
The guide bushing spindle synchronization temporary cancel signal was turned ON/OFF when the master spin-
dle and the guide bushing spindle were in one of the following modes.
During rotation (when not stopped)
During tap cycle synchronization mode
During spindle synchronization mode
During tool-spindle synchronization I (polygon machining) mode
During tool-spindle synchronization II (hobbing) mode
During spindle C axis control C axis mode
During orientation/indexing
Remedy
Check the ladder program.
M01

GB SP sync runs independently

Details
The reference spindle was commanded as a spindle related to tool spindle synchronization IC (polygon).
The guide bushing spindle was commanded as a synchronous tapping spindle.
The guide bushing spindle was commanded as a spindle related to spindle synchronization/tool spindle
synchronization I (polygon)/tool spindle synchronization II (hobbing).
Remedy
Check the program.
M01

Cmds illegal in spindle synchr

Details
Synchronous tapping was issued for the reference spindle or the synchronized spindle during spindle synchro-
nization.
Remedy
Cancel the synchronous tapping.
M01
Operation non-continuable(STO)
Details
An axis in STO state exists in the part system.
Remedy
Release the STO state and reset the NC.
M01
Prog check: work posn error
Details
When the NC reset signal is input with the High-speed simple program check: Coordinate position check ON
signal (Y76B) set to ON, the workpiece coordinate position is different from the position at the program start.
Remedy
Correct the machining program.