16 Machine Parameters
#2619

thr_clamp

Specify the maximum cutting feed rate to be applied to thread cutting for each axis.
---Setting range---
1 to 1000000
#2620
thr_t
Specify the primary delay time constant to be used in acceleration/deceleration of a thread cut axis.
* This parameter is enabled when either C1 (Primary delay cutting feed) or LC (Linear acceleration/deceler-
ation cutting feed) is selected for the acceleration/deceleration mode (#2003 smgst).
---Setting range---
0 to 4000
#2621

plrapid2

Specify the rapid traverse rate to be applied under 2-axis superimposition control when the axis traverses in
the same direction as the other axis that is travelling at a cutting feed rate.
---Setting range---
0 to 1000000(mm/min)
#2622
pl3G0tL
Specify the G0 time constant (linear) to be applied under 3-axis serial superimposition control.
---Setting range---
0 to 4000(ms)
#2623
pl3G0t1
Specify the G0 time constant (primary delay) to be applied under 3-axis serial superimposition control.
---Setting range---
0 to 5000(ms)
#2624
pl3G1tL
Specify the G1 time constant (linear) to be applied under 3-axis serial superimposition control.
---Setting range---
0 to 4000(ms)
#2625
pl3G1t1
Specify the G1 time constant (primary delay) to be applied under 3-axis serial superimposition control.
---Setting range---
0 to 5000(ms)
#2626
pl3rapid
Specify the rapid traverse rate to be applied when all the three superimposed axes are rapid-traversing in a
single direction under 3-axis serial superimposition control.
---Setting range---
0 to 1000000(mm/min)
#2627
pl3rapid2
Specify the rapid traverse rate to be applied under 3-axis serial superimposition control when two of the three
superimposed axes are rapid-traversing while the remaining one axis is fed at a cutting feed rate in a single
direction.
---Setting range---
0 to 1000000(mm/min)
IB-1501279-H
Thread cut clamp speed
Thread cut time constant
Rapid traverse rate for superimposition control 2
G0 time constant (linear) for 3-axis serial superimposi-
tion control
G0 time constant (primary delay) for 3-axis serial super-
imposition control
G1 time constant (linear) for 3-axis serial superimposi-
tion control
G1 time constant (primary delay) for 3-axis serial super-
imposition control
Rapid traverse rate for 3-axis serial superimposition
control
Rapid traverse rate for 3-axis serial superimposition
control 2