M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
#1224
aux08
bit0: Sampling data output
Select whether to enable the sampling data output.
0: Disable
1: Enable
#1225
aux09
bit7: Enable/disable spindle rotation speed clamp
Select whether to enable the spindle rotation speed clamp by the G92 S or Q command for the spindle com-
mand rotation speed (R7000) set with the user ladder.
0: Enable
1: Disable
#1226
aux10
bit0: Tool compensation data for external workpiece coordinate offset measurement
Select the tool compensation data to be used for external workpiece coordinate offset measurement.
0: Tool length data and tool nose wear data
1: Tool length data
bit1: Optional block skip type
Select whether to enable the optional block skip in the middle of a block.
0: Enable only at the beginning of a block.
1: Enable in the middle of a block, as well as at the beginning of the block.
Note that a slash "/" in an equation between [ ] is handled as division operator.
(Note) This parameter is enabled when "#1274 ext10/bit4" is "0".
bit2: Single block stop timing
Select the timing at which the single block signal is activated.
0: When the signal goes ON while automatic operation is starting, the block will stop after finished.
1: When the signal is ON at the end of the block, the block will stop.
bit3: C-axis reference position return type
Select the C-axis reference position return type.
0: Basic position return is performed by the G28 reference position return command or by activating the
manual reference position return. The basic point dog is used.
1: When the first C-axis command is issued after the C-axis mode is entered in automatic mode, reference
position return is performed before the execution of the block. The reference position return is also per-
formed by the G28 reference position return command or by activating the manual reference position
return. The Z phase of the encoder is used.
bit4: S command during constant surface speed
Select whether to output a strobe signal when the S command is issued in constant surface speed mode.
0: Not output any strobe signal in constant surface speed mode.
1: Output strobe signals in constant surface speed mode.
bit5: Arbitrary allocation of dog signal
Select whether to enable the arbitrary allocation parameter for the origin dog and H/W OT.
0: Disable (Fixed device is used.)
1: Enable (Device is specified by the parameter.)
bit6:
Not used.
bit7: Shorten JOG stop time
Specify whether to shorten the JOG stop time.
0: Do not shorten the JOG stop time. (Same as before)
1: Shorten the JOG stop time.