Interference Data Unspecified; Interf. 3D Objects Count Error; Interfere Check Iii: Time Over; Interfere: Control Axis Error - Mitsubishi Electric M800 Series Manual

Hide thumbs Also See for M800 Series:
Table of Contents

Advertisement

M800/M80/E80/C80 Series Alarm/Parameter Manual
1 Operation Errors (M)
M03

Interference data unspecified

Details
You attempted to turn ON the interference check III mode with the interfering object data disabled.
Remedy
Execute the interference data ON command to enable the interference data before turning ON the inter-
ference check III mode.
M03

Interf. 3D objects count error

Details
The total number of solid objects used as interfering object has exceeded the maximum.
Remedy
The total number of interfering solid objects set in the system variable or R register has exceeded the max-
imum. Correct the setting.
M03

Interfere check III: time over

Details
The allowable process time for interference check III has been exceeded.
Remedy
Turn OFF the interference check III mode.
Correct the interfering object definition.
M03

Interfere: control axis error

Details
In the interfering object definition, the IJK control axes have been set as follows:
Nonexistent axis name (an axis not set in the base axis specification parameter "#1022 axname2")
I, J and K axes belong to different part systems
Rotary axis
Remedy
Correct the setting of the IJK control axes in the interfering object definition.
M03
Interf:2 rot axes in cylinder
Details
In the interfering object definition, two or more rotary axes have been set for the cylindrical solid definition No.
Remedy
Correct the solid designation and the setting of the IJK axis rotation angle in the interfering object definition.
M03
Interfere:2 rot axes in cuboid
Details
In the interfering object definition, two or more rotary axes have been set for the cuboidal solid definition No.
Remedy
Correct the setting of the IJK axis rotation angle in the interfering object definition.
M03
Interfere: rotary axis error
Details
In the interfering object definition, the IJK rotary axes have been set as follows:
Nonexistent axis name
(an axis not set in the base axis specification parameter (#1022 axname2))
Linear axis
All three axes are rotary axes
Remedy
Correct the setting of the IJK rotary axes in the interfering object definition.
1001
1002
1003
2001
2002
2003
2004
35
Interference object defi-
nition number
Interference object defi-
nition number
Interference object defi-
nition number
Interference object defi-
nition number
IB-1501279-H

Hide quick links: