M800/M80/E80/C80 Series Alarm/Parameter Manual
12 Program Errors (P)
P173
G10 P number error
Details
The compensation No. at the G10 command is not within the permitted number of sets in the specifications.
Remedy
Check the number of sets for the tool compensation Nos. and correct the address P designation to be with-
in the number of sets.
P174
No spec:Comp input by prog G11
Details
Compensation data input by program cancel (G11) was commanded though there is no specification of com-
pensation data input by program.
Remedy
Check the specifications.
P177
Tool life count active
Details
Registration of tool life management data with G10 was attempted when the "usage data count valid" signal
was ON.
Remedy
The tool life management data cannot be registered during the usage data count. Turn the "usage data
count valid" signal OFF.
P178
Tool life data entry over
Details
The number of registration groups, total number of registered tools or the number of registrations per group
exceeded the range in the specifications.
Remedy
Correct the number of registrations.
P179
Illegal group No.
Details
A duplicate group No. was found at the registration of the tool life management data with G10.
A group No. that was not registered was designated during the T****99 command.
An M code command, which must be issued as a single command, coexists in the same block as that of
another M code command.
The M code commands set in the same group exist in the same block.
Remedy
Register the tool life data once for one group: commanding with a duplicate group No. is not allowed.
Correct to the group No.
P180
No spec: Drilling cycle
Details
A fixed cycle command (G72 - G89) was issued though it is out of specifications.
Remedy
Check the specifications.
Correct the program.
P181
No spindle command (Tap cycle)
Details
Spindle rotation speed (S) has not been commanded in synchronous tapping.
Remedy
Command the spindle rotation speed (S) in synchronous tapping.
When "#8125 Check Scode in G84" is set to "1", enter the S command in the same block where the syn-
chronous tapping command is issued.
IB-1501279-H
134