M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
(PR)
#2182

sscfeed2

Set the observation speed, which is at the machine end, in the multi-step speed monitor.
(Note 1) When the setting value is larger than 18000, the last 2 digits will be ignored.
Ex. 1234567 -> 1234500(mm/min, °/min)
(Note 2) Observation speeds (#2181 to #2186 and #2191 to #2192) need to satisfy the following condition.
If not satisfied, the alarm (Y20 0007) will result.
sscfeed1 8
SV018:PIT
---Setting range---
0 to 6553500 (mm/min or °/min)
(PR)
#2183

sscfeed3

Set the observation speed, which is at the machine end, in the multi-step speed monitor.
(Note 1) When the setting value is larger than 18000, the last 2 digits will be ignored.
Ex. 1234567 -> 1234500(mm/min, °/min)
(Note 2) Observation speeds (#2181 to #2186 and #2191 to #2192) need to satisfy the following condition.
If not satisfied, the alarm (Y20 0007) will result.
sscfeed1 8
SV018:PIT
---Setting range---
0 to 6553500 (mm/min or °/min)
(PR)
#2184

sscfeed4

Set the observation speed, which is at the machine end, in the multi-step speed monitor.
(Note 1) When the setting value is larger than 18000, the last 2 digits will be ignored.
Ex. 1234567 -> 1234500(mm/min, °/min)
(Note 2) Observation speeds (#2181 to #2186 and #2191 to #2192) need to satisfy the following condition.
If not satisfied, the alarm (Y20 0007) will result.
sscfeed1 8
SV018:PIT
---Setting range---
0 to 6553500 (mm/min or °/min)
(PR)
#2185

sscfeed5

Set the observation speed, which is at the machine end, in the multi-step speed monitor.
(Note 1) When the setting value is larger than 18000, the last 2 digits will be ignored.
Ex. 1234567 -> 1234500(mm/min, °/min)
(Note 2) Observation speeds (#2181 to #2186 and #2191 to #2192) need to satisfy the following condition.
If not satisfied, the alarm (Y20 0007) will result.
sscfeed1 8
SV018:PIT
---Setting range---
0 to 6553500 (mm/min or °/min)
SV002:PC2
×
32767
SV001:PC1
SV002:PC2
×
32767
SV001:PC1
SV002:PC2
×
32767
SV001:PC1
SV002:PC2
×
32767
SV001:PC1
491
Observation speed 2
Observation speed 3
Observation speed 4
Observation speed 5