M800/M80/E80/C80 Series Alarm/Parameter Manual
2 Stop Codes (T)
T01
Operation mode duplicated
Details
Two or more automatic operation modes have been selected.
Remedy
Check for any short circuit in the mode (memory, tape, MDl) selection signal line.
Check for any failure in the switch.
Correct the sequence program.
T01
Operation mode changed
Details
The automatic operation mode has changed to another automatic operation mode.
Remedy
Return to the original automatic operation mode, and execute automatic start.
T01
Tape search execution
Details
Automatic start is not possible as tape search is being executed.
Remedy
Wait for the tape search to be completed and then execute the automatic start.
T01
Cycle start prohibit
Details
Automatic start is disabled because restart search is in execution.
Remedy
Execute automatic start after the restart search is completed.
T01
CNC overheat
Details
Automatic start is not possible because a thermal alarm (Z53 CNC overheat) has occurred.
Remedy
Temperature of the control unit has exceeded the specified temperature.
Take appropriate measures to cool the unit.
T01
Cycle st. prohibit(Host comm.)
Details
Automatic start cannot is not possible because the NC is communicating with the host computer.
Remedy
Wait for the communication with host computer to be ended and then execute the automatic start.
T01
Cycle st prohibit(Battery alm)
Details
Automatic start is not possible because the voltage of the battery in the NC control unit has dropped.
Remedy
Replace the battery of the NC control unit.
Contact the service center.
T01
R-pnt offset value not set
Details
Automatic operation is not possible because no reference position offset value has been set.
Remedy
Perform the reference position initialization setting, then set "#2034 rfpofs(Distance-coded reference po-
sition detection offset)".
39
0108
0109
0110
0111
0113
0115
0116
0117
IB-1501279-H