M800/M80/E80/C80 Series Alarm/Parameter Manual
1 Operation Errors (M)
M01
Restart switch ON
Details
Restart switch has been turned ON and manual mode has been selected before the restart search is complet-
ed.
Remedy
Search the block to restart.
Turn the restart switch OFF.
M01
Program check mode
Details
The cycle start button was pressed during program check or in program check mode.
Remedy
Press the reset button to cancel the program check mode.
M01
Cycle st. in buffer correct
Details
The cycle start button was pressed during buffer correction.
Remedy
Press the cycle start button after the buffer correction is completed.
M01
In reset process
Details
The cycle start button was pressed during resetting or tape rewinding.
Remedy
When rewinding the tape, wait for the winding to end, or press the reset button to stop the winding, and
then press the cycle start button.
During resetting, wait for the resetting to end, and then press the automatic start button.
M01
Playback not possible
Details
The playback switch was turned ON during editing.
Remedy
Cancel the editing by pressing the input or previous screen key before turning ON the playback switch.
M01
Turn stop in normal line cntrl
Details
The turning angle at the block joint exceeded the limit during normal line control.
In normal line control type I:
The parameter "#1523 C_feed" (Normal line control axis turning speed) has not been set.
In normal line control type II:
When turning in the inside of the arc, the set value for the parameter "#8041 C-rot. R" is larger than the arc
radius.
Remedy
Correct the program.
Correct the parameter "#1523 C_feed" (Normal line control axis turning speed) setting.
Correct the parameter "#8041 C-rot. R" setting.
M01
Reverse run impossible
Details
Any of the following conditions are occurring.
a) There is no block to run backward
b) Eight blocks without a travel command continued
Remedy
Execute forward run to clear the alarm.
Reset to clear the alarm.