Minute Lengs (For M System Only); Fairing On (For M System Only); Corjudgel (For M System Only) - Mitsubishi Electric M800 Series Manual

Hide thumbs Also See for M800 Series:
Table of Contents

Advertisement

M800/M80/E80/C80 Series Alarm/Parameter Manual
15 User Parameters
#8030

MINUTE LENGS (for M system only)

Set the fine-segment length where the spline interpolation is temporarily canceled.
When the length of one block exceeds this parameter setting value, spline interpolation is canceled tempo-
rarily and linear interpolation is performed. Set a value a little smaller than one block length of the program.
If "-1" is set, spline interpolation will be performed regardless of block length.
---Setting range---
-1 to 127 (mm)
0: 1 (mm)
#8033

Fairing ON (for M system only)

Select whether or not to use the fairing or smooth fairing function.
0: Use neither of them
1: Use the fairing function
2: Use the smooth fairing function
#8037

CorJudgeL (for M system only)

Set the length of the block to be excluded when deciding a corner.
(Enabled when "#8036 CordecJudge" is set to "1".)
---Setting range---
0 to 99999.999 (mm)
#8090
SSS ON (for M system only)
Set whether to enable the SSS control with G05 P10000.
0: Disable
1: Enable
#8091
StdLength (for M system only)
Set the maximum value of the range for recognizing the shape.
To eliminate the effect of steps or errors, etc., set a large value. To enable sufficient deceleration, set a small
value.
If "0.000" is set, the standard value (1.000mm) will be applied.
---Setting range---
0 to 100.000 (mm)
#8093
StepLeng (for M system only)
Set the width of the step at which the speed is not to be decelerated. (Approximately the same as the CAM
path difference [Tolerance].)
If "0" is set, the standard value (5μm) will be applied.
If a minus value is set, the speed will decelerate at all minute steps.
---Setting range---
-1.000 to 0.100 (mm)
#12070
Sfilt2_tol
Specify the time constant of the filter that smoothes out fluctuations in acceleration under the tolerance con-
trol.
Basically set to 0.
---Setting range---
0 to 200 (ms)
#42001
P1-G1btL
Time constant for machining condition selection I
Set the time constant for the machining condition selection I function. This is equivalent to the parameter
#1207 G1btL.
---Setting range---
Without high-accuracy control time constant expansion: 0 to 5000 (ms)
With high-accuracy control time constant expansion: 0 to 30000 (ms)
Tolerance control: Soft acceleration/deceleration filter
2
Time constant for machining condition selection I
321
IB-1501279-H

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

C80 seriesM80 seriesE80 series

Table of Contents