Mitsubishi Electric M800 Series Manual page 572

Hide thumbs Also See for M800 Series:
Table of Contents

Advertisement

M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
#3060
sptc7
Set the speed which switches from 7th step to 8th step in spindle synchronization multi-step acceleration/
deceleration control. Set the same value for the reference axis and synchronous axis.
Set the value of limit rotation speed (slimit) or higher not to carry out a step shift.
---Setting range---
0 to 99999 (r/min)
#3061
spdiv1
Set the acceleration/deceleration time constant to be used at the speed of changeover speed 1 (sptc1) and
higher in spindle synchronization multi-step acceleration/deceleration control. Set this as a magnification in
relation to the spindle synchronization acceleration/deceleration time constant (spt).
---Setting range---
0 to 127
#3062
spdiv2
Set the acceleration/deceleration time constant to be used at the speed of changeover speed 2 (sptc2) and
higher in spindle synchronization multi-step acceleration/deceleration control. Set this as a magnification in
relation to the spindle synchronization acceleration/deceleration time constant (spt).
---Setting range---
0 to 127
#3063
spdiv3
Set the acceleration/deceleration time constant to be used at the speed of changeover speed 3 (sptc3) and
higher in spindle synchronization multi-step acceleration/deceleration control. Set this as a magnification in
relation to the spindle synchronization acceleration/deceleration time constant (spt).
---Setting range---
0 to 127
#3064
spdiv4
Set the acceleration/deceleration time constant to be used at the speed of changeover speed 4 (sptc4) and
higher in spindle synchronization multi-step acceleration/deceleration control. Set this as a magnification in
relation to the spindle synchronization acceleration/deceleration time constant (spt).
---Setting range---
0 to 127
#3065
spdiv5
Set the acceleration/deceleration time constant to be used at the speed of changeover speed 5 (sptc5) and
higher in spindle synchronization multi-step acceleration/deceleration control. Set this as a magnification in
relation to the spindle synchronization acceleration/deceleration time constant (spt).
---Setting range---
0 to 127
#3066
spdiv6
Set the acceleration/deceleration time constant to be used at the speed of changeover speed 6 (sptc6) and
higher in spindle synchronization multi-step acceleration/deceleration control. Set this as a magnification in
relation to the spindle synchronization acceleration/deceleration time constant (spt).
---Setting range---
0 to 127
#3067
spdiv7
Set the acceleration/deceleration time constant to be used at the speed of changeover speed 7 (sptc7) and
higher in spindle synchronization multi-step acceleration/deceleration control. Set this as a magnification in
relation to the spindle synchronization acceleration/deceleration time constant (spt).
---Setting range---
0 to 127
Spindle synchronization multi-step acceleration/decel-
eration changeover speed 7
Time constant magnification for changeover speed 1
Time constant magnification for changeover speed 2
Time constant magnification for changeover speed 3
Time constant magnification for changeover speed 4
Time constant magnification for changeover speed 5
Time constant magnification for changeover speed 6
Time constant magnification for changeover speed 7