Mitsubishi Electric M800 Series Manual page 460

Hide thumbs Also See for M800 Series:
Table of Contents

Advertisement

M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
#1413
M_wait[M095-064]
Register an M code (64 to 95) that needs special operation.
Each bit of the setting value corresponds to the M code number.
(Example) To register M05, set 00000020 in #1411.
(Note) Note that the registered M code operation varies according to M_mode (#1401).
---Setting range---
0 to FFFFFFFF
Set this in hexadecimal format.
#1414
M_wait[M127-096]
Register an M code (96 to 127) that needs special operation.
Each bit of the setting value corresponds to the M code number.
(Example) To register M05, set 00000020 in #1411.
(Note) Note that the registered M code operation varies according to M_mode (#1401).
---Setting range---
0 to FFFFFFFF
Set this in hexadecimal format.
#1415
M_wait[M159-128]
Register an M code (128 to 159) that needs special operation.
Each bit of the setting value corresponds to the M code number.
(Example) To register M05, set 00000020 in #1411.
(Note) Note that the registered M code operation varies according to M_mode (#1401).
---Setting range---
0 to FFFFFFFF
Set this in hexadecimal format.
#1416
M_wait[M191-160]
Register an M code (160 to 191) that needs special operation.
Each bit of the setting value corresponds to the M code number.
(Example) To register M05, set 00000020 in #1411.
(Note) Note that the registered M code operation varies according to M_mode (#1401).
---Setting range---
0 to FFFFFFFF
Set this in hexadecimal format.
#1417
M_wait[M223-192]
Register an M code (192 to 223) that needs special operation.
Each bit of the setting value corresponds to the M code number.
(Example) To register M05, set 00000020 in #1411.
(Note) Note that the registered M code operation varies according to M_mode (#1401).
---Setting range---
0 to FFFFFFFF
Set this in hexadecimal format.
#1418
M_wait[M255-224]
Register an M code (224 to 255) that needs special operation.
Each bit of the setting value corresponds to the M code number.
(Example) To register M05, set 00000020 in #1411.
(Note) Note that the registered M code operation varies according to M_mode (#1401).
---Setting range---
0 to FFFFFFFF
Set this in hexadecimal format.
Special operation registration M code
Special operation registration M code
Special operation registration M code
Special operation registration M code
Special operation registration M code
Special operation registration M code
443
IB-1501279-H

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

C80 seriesM80 seriesE80 series

Table of Contents