M800/M80/E80/C80 Series Alarm/Parameter Manual
13 Smart Safety Observation Alarm (V)
V03
Slave station comm. error 2
Details
The data received by the safety I/O unit is incorrect. The screen displays the unit No. and RIO system with an
error.
bit24-27: Unit No.
bit16-17: Detected system
Safety observation target axes are stopped, and all the DOs of the safety I/O unit concerned are turned OFF.
Remedy
NC unit or safety I/O unit may be faulty. Exchange the NC unit or safety I/O unit.
V03
Slave station comm. error 3
Details
The data received by the safety I/O unit is incorrect. The screen displays the unit No. and RIO system with an
error.
bit24-27: Unit No.
bit16-17: Detected system
Safety observation target axes are stopped, and all the DOs of the safety I/O unit concerned are turned OFF.
Remedy
NC unit or safety I/O unit may be faulty. Exchange the NC unit or safety I/O unit.
V03
Slave station data compare err
Details
The data received by the safety I/O unit is inconsistent. The screen displays the unit No. and RIO system with
an error.
bit24-27: Unit No.
bit16-17: Detected system
Safety observation target axes are stopped, and all the DOs of the safety I/O unit concerned are turned OFF.
Remedy
Check the user safety sequence circuit to see if the output signal control circuit is correct.
Data corruption may have been caused due to noise. Take anti-noise measures on the connection be-
tween the NC unit and safety I/O unit.
NC unit or safety I/O unit may be faulty. Exchange the NC unit or safety I/O unit.
V03
Output OFF check error
Details
Output signal of the safety I/O unit fails to be OFF. The screen displays the unit No., RIO system and signal bit
with an error.
[M8]
bit24-27: Unit No.
bit16-17: Detected system
bit0-15: Signal BIT
[C80]
bit0-31: Signal BIT
Safety observation target axes are stopped.
Remedy
NC unit or safety I/O unit may be faulty. Exchange the NC unit or safety I/O unit.
IB-1501279-H
0002
0003
0004
0005
164
Unit info
Unit info
Unit info
Unit info