15 User Parameters
#19426

ManualB Std F1

This sets the rotary axis speed for surface speed control standard radius 1 (ManualB Std R1).
When the setting value of #19426 is larger than that of "#19428 ManualB Std F2", #19426 setting will be used
as surface speed control standard speed 2: #19427 setting will be used as surface speed control standard
speed 1.
---Setting range---
1 to 1000000 (°/min)
#19427

ManualB Std R2

Set a radius used as standard for the rotary axis speed.
When the same value is set as "#19425 ManualB Std R1", the surface speed control standard speed 1 (Man-
ualB Std F1) will be selected as the rotary axis speed if the radius is less than that value. The surface speed
control standard speed 2 (ManualB Std F2) is selected if larger than the set value.
---Setting range---
0 to 99999.999 (mm)
#19428

ManualB Std F2

Set the rotary axis speed for surface speed control standard radius 2 (ManualB Std R2).
---Setting range---
1 to 1000000 (°/min)