16 Machine Parameters
(PR)
#1279
ext15
bit0: Part system synchronization method
Select the part system synchronization method.
0: If one part system is not in the automatic operation, the synchronization command will be ignored and
the next block will be executed.
1: Operate according to the "waiting ignore" signal.
If the "waiting ignore" signal is set to "1", the synchronization command will be ignored. When set to "0",
synchronization will be applied.
bit1: Interrupt amount during machine lock
Select when to cancel the interruption amount during machine lock.
0: When resetting
1: During manual reference position return (not when resetting)
bit2: Selection of cutting start interlock target block
Select whether to enable the cutting start interlock for successive cutting blocks.
0: Enable
1: Disable
bit4: Dry run OFF during thread cutting
Select whether to enable or disable dry run during thread cutting.
0: Enable dry run
1: Disable dry run
bit5: Cancel G92 shift distance
Select whether to clear the G92 (coordinate system setting) shift distance when the manual reference posi-
tion is reached.
0: Not clear
1: Clear
bit6: Enable single block stop at middle point
Set whether to enable/disable single block stop at the middle point of G28/G29/G30.
0: Disable single block stop
1: Enable single block stop
bit7: Retain G52 at manual reference position return
Select whether to retain the local coordinate system setting (G52) at the time of manual reference position
arrival. This parameter is enabled when #1279 ext15/bit5 is 1.
0: Not retain (Cancel)
1: Retain