Mitsubishi Electric M800 Series Manual page 369

Hide thumbs Also See for M800 Series:
Table of Contents

Advertisement

M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
#1195
Mmac
Select whether to enable or disable M command macro call of user macro.
0: Disable
1: Enable
#1196
Smac
Select whether to enable or disable S command macro call of user macro.
0: Disable
1: Enable
#1197
Tmac
Select whether to enable a call of user macro using command T.
0: Disable macro call
1: Enable macro call, irrespective of the number of command T digits
2: Enable macro call when a tool No. (excluding 0) is given to the upper digit of command T
3: Enable macro call when a tool No. (including 0) is given to the upper digit of command T.
#1198
M2mac
Select whether to enable or disable 2nd miscellaneous command macro call of user macro.
0: Disable
1: Enable
#1199
Sselect
Select the initial condition of spindle control after power is turned ON.
0: 1st spindle control mode (G43.1)
1: 2nd spindle control mode (G44.1)
2: All spindle simultaneously control mode (G47.1)
(Note) While G43.1 or G44.1 command is given, the spindle No. is selected with "#12090 SnG43.1" or "#1534
SnG44.1".
(PR)
#1200
G0_acc
Select the acceleration and deceleration type when a rapid traverse command is issued.
0: Acceleration and deceleration with constant time (conventional type)
1: Acceleration and deceleration with a constant angle of inclination
(Note) When rapid traverse constant inclination multi-step acceleration/deceleration is valid, this parameter
will be invalid.
(PR)
#1201
G1_acc
Select the acceleration and deceleration type when a linear interpolation command is issued.
0: Acceleration and deceleration with constant time (conventional type)
1: Acceleration and deceleration with a constant angle of inclination
#1202
mirofs
Set the distance between tools (edges) (between facing turrets).
---Setting range---
0 to 99999.999 (mm)
#1203
TmirS1
Select the turrets, which correspond to the tool Nos. 1 to 32, as facing turrets for T code mirror image.
---Setting range---
0 to FFFFFFFF
IB-1501279-H
Macro call for M command
Macro call for S command
Macro call by command T
Macro call with 2nd miscellaneous code
Select initial spindle control
Validate acceleration and deceleration with inclination
constant G0
Validate acceleration and deceleration with inclination
constant G1
Distance between facing turrets (for L system only)
Select turrets as facing turrets with T command (for L
system only)
352

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

C80 seriesM80 seriesE80 series

Table of Contents