13 Smart Safety Observation Alarm (V)
V53

Warning on 24Hr continuous ON

Details
Output signal of the safety I/O unit has been kept ON for 24 hours or longer.
The screen displays the unit No., RIO system and signal BIT that are subject to the warning.
[M8]
bit28-31: None
bit24-27: Unit No.
bit18-23: None
bit16-17: Detected system
bit0-15: Signal BIT
[C80]
bit0-31: Signal BIT
Remedy
Turn OFF the output signal concerned through the user safety sequence, or use the output OFF check
function to make sure that the output signal turns OFF.
V54

Simple test mode is active

Details
Smart safety observation target axis (the parameters "#51101 SF_Disable" = 0 / "#51301 SF_SDisable" =
0) is defined as a hypothetical axis (the parameter "#51015 safe_drv_test" = 1). In this case some alarms
fail to occur, thus avoid this setting while a drive unit is being connected.
NC system is set to a simulation mode (the parameter "#1168 test" = 1 ). During this mode some alarms
fail to occur, thus do not use this mode while a safety I/O unit is connected.
Remedy
Connect MDS-E Series drive to all the axes subject to safety observation, set the parameter ("#51015
safe_drv_test" = 0) and then turn OFF and ON the power.
Connect a safety I/O unit, set the parameter ("#1168 test" = 0) and then turn OFF and ON the power.
IB-1501279-H
0001
0001