M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
#13229
SP229 SFNC9
Select the spindle functions.
Functions are allocated to each bit.
Set this in hexadecimal format.
bit F-E :
Not used. Set to "0".
bit D : rps Safely limited speed setting unit
0: Normal 1: 100°/min
bit C : sdt2 Specified speed output digital signal 2 output
0: Normal 1: Enable
bit B-9 :
Not used. Set to "0".
bit 8 : sto Dedicated wiring STO function
Set this parameter to use dedicated wiring STO function.
0: Dedicated wiring STO function unused
(Only for MDS-E/EH and MDS-EJ/EJH)
bit 7-1 :
Not used. Set to "0".
bit 0 : omrffon OMR-FF control enabled
0: Disable 1: Enable
#13230
SP230 SFNC10
Select the spindle functions.
Functions are allocated to each bit.
Set this in hexadecimal format.
bit F-C :
Not used. Set to "0".
bit B : pfdsr
Set the spindle stop operation at a power failure when the deceleration and stop function at power failure is
enabled.
Normal (Coast to a stop at power failure) : 0
Deceleration and stop at power failure
bit A-9 :
Not used. Set to "0".
bit 8 : nohis History of communication error alarm between NC and DRV(34,36,38,39)
0: Enable 1: Disable
bit 7 : cse Spindle C axis command speed monitoring function
0: Normal setting (function disabled) 1: Function enabled
bit 6-0 :
Not used. Set to "0".
Related parameters: SP055, SP056
Spindle function 9
omrffon
sto
sdt2
rps
1: Dedicated wiring STO function used
Spindle function 10
cse
nohis
pfdsr
: 1
615
IB-1501279-H