M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
#1130
set_t
Select the tool command value display on the monitor screen.
0: Display T-modal value of program command
1: Display Tool No. sent from PLC
#1132
brightness
Select the brightness of display unit.
1: High brightness (in bright state)
0: Medium brightness
-1: Low brightness (in dim state)
#1133
ofsmem
Not used. Set to "0".
#1134
LCDneg
Not used. Set to "0".
#1135
unt_nm
Set the unit name.
Set with 4 or less characters consisting of both alphabets and numbers.
If "0" is set, the unit name won't be displayed.
---Setting range---
4 or less characters consisting of both alphabets and numbers
#1136
optype
Not used. Set to "0".
#1137
Cntsel
Not used. Set to "0".
#1138
Pnosel
Not used. Set to "0".
#1139
edtype
Not used. Set to "0".
#1140
Mn100
Set the first number of M code that corresponds to the setup Nos. from 100 to 199.
---Setting range-
0 to 99999999
#1141
Mn200
Set the first number of M code that corresponds to the setup Nos. from 200 to 299.
---Setting range---
0 to 99999999
#1142
Mn300
Set the first number of M code that corresponds to the setup Nos. from 300 to 399.
---Setting range---
0 to 99999999
#1143
Mn400
Set the first number of M code that corresponds to the setup Nos. from 400 to 499.
---Setting range---
0 to 99999999
#1144
mdlkof
Select whether to enable MDI setting in non-MDI mode.
0: Disable MDI setting
1: Enable MDI setting
IB-1501279-H
Display selected tool number
Unit name
M code number
M code number
M code number
M code number
MDI setup lock
386