16 Machine Parameters
#43004
SGRA3
This ratio is enabled under turret gear change control.
Specify the number of spindle-side gear teeth for gear selection command GI1=0/GI2=0.
When 0 is set, the operation will be the same as when 1 is set.
---Setting range---
0 to 32767
#43005
SGRA4
This ratio is enabled under turret gear change control.
Specify the number of spindle-side gear teeth for gear selection command GI1=0/GI2=0.
When 0 is set, the operation will be the same as when 1 is set.
---Setting range---
0 to 32767
#43006
SGRB1
This ratio is enabled under turret gear change control.
Specify the number of teeth of the motor shaft side gear 1 for gear selection command GI1=0/GI2=0.
When 0 is set, the operation will be the same as when 1 is set.
---Setting range---
0 to 32767
#43007
SGRB2
This ratio is enabled under turret gear change control.
Specify the number of teeth of the motor shaft side gear 1 for gear selection command GI1=0/GI2=0.
When 0 is set, the operation will be the same as when 1 is set.
---Setting range---
0 to 32767
#43008
SGRB3
This ratio is enabled under turret gear change control.
Specify the number of teeth of the motor shaft side gear 1 for gear selection command GI1=0/GI2=0.
When 0 is set, the operation will be the same as when 1 is set.
---Setting range---
0 to 32767
#43009
SGRB4
This ratio is enabled under turret gear change control.
Specify the number of teeth of the motor shaft side gear 1 for gear selection command GI1=0/GI2=0.
When 0 is set, the operation will be the same as when 1 is set.
---Setting range---
0 to 32767
#43046
smax_tap1
Specify the maximum rotation speed in synchronous tapping multi-step acceleration/deceleration control
when gear 00 is selected.
Inclination of 3rd linear acceleration/deceleration control is determined by the ratio of smax_tap1(#43046)
and tapt31(#3045).
When 0 is set to smax_tap1, use smax1(#3005).
When smax_tap1 is smax1 or more, use smax1.
---Setting range---
0 to 99999 (r/min)
#43047
smax_tap2
Specify the maximum rotation speed in synchronous tapping multi-step acceleration/deceleration control
when gear 01 is selected.
Inclination of 3rd linear acceleration/deceleration control is determined by the ratio of smax_tap2(#43047)
and tapt32(#3046).
When 0 is set to smax_tap2, use smax2(#3006).
When smax_tap2 is smax2 or more, use smax2.
---Setting range---
0 to 99999 (r/min)
Spindle-side gear ratio 3
Spindle-side gear ratio 4
Motor shaft-side gear ratio 1
Motor shaft-side gear ratio 2
Motor shaft-side gear ratio 3
Motor shaft-side gear ratio 4
Synchro tapping spindle Max rotation speed (Gear: 00)
Synchro tapping spindle Max rotation speed (Gear: 01)