M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
(PR)
#1397
H3_pno
Specify the connection destination of the 3rd handle.
bit F to 8: Remote I/O unit station 1 to 40(HEX)
bit 7 to 4: Handle connection destination
0: CNC unit
1 to 2: Remote I/O unit
5: Expansion unit
F: Operation panel I/O unit
bit 3 to 0: Handle connection channel 1 to 3 (3 is only valid for operation panel)
(Ex)
0001: Handle 1 connected to the CNC unit
2421: Handle 1 of 36th station for remote I/O unit connected to RIO2
00F3: Handle 3 of operation panel I/O unit connected to RIO3
(Note 1) When the specified destination is not implemented, handle movement is not performed.
(Note 2) When all the H1_pno to H3_pno are set to 0000, handles are automatically allocated.
Other than above, 0000 setting is the same connection as 0001 setting.
---Setting range---
0x0000 to 0xFFFF
#1399
sp_filt
Specify the average filter scale factor for the spindle's actual rotation speed data.
If the scale factor increases, fluctuations in speed display are mitigated.
0: Standard setting
1: 0.5-fold
2: 1-fold
3: 2-fold
4: 4-fold
5: 8-fold
#1401
M_mode
Select the M command operation.
(Note) Register M codes in the special operation registration M codes (#1411 to #1418).
0: Not wait for the completion of registered M codes,
but wait for the completion of the other M codes
1: Wait for the completion of registered M codes,
but not wait for the completion of the other M code
#1402
S_mode
Select the S command completion method.
0: Wait for the complete signal from PLC
1: Not wait for the complete signal from PLC
#1403
T_mode
Select the T command completion method.
0: Wait for the complete signal from PLC
1: Not wait for the complete signal from PLC
#1404
M2_mode
Select the 2nd miscellaneous command completion method.
0: Wait for the complete signal from PLC
1: Not wait for the complete signal from PLC
3rd handle selection
Spindle's actual rotation speed filter
M command operation selection
S command completion method selection
T command completion method selection
2nd miscellaneous command completion method se-
lection
441