Rotary Axis Para Unswitchable; Interference Check Invalidated; Machine Interference 1; Tool Interfere. Check Disabled - Mitsubishi Electric M800 Series Manual

Hide thumbs Also See for M800 Series:
Table of Contents

Advertisement

M800/M80/E80/C80 Series Alarm/Parameter Manual
1 Operation Errors (M)
M01

Rotary axis para unswitchable

Details
The rotary axis configuration parameter switch request signal has turned ON for a part system where any of
the following modes is active.
Tool center point control mode
Inclined surface machining mode
Workpiece installation error compensation mode
Tool axis direction tool length compensation mode
Simple inclined surface machining mode
3D radius compensation mode
3D manual feed
Tool handle feed & interruption
R-Navi mode
Remedy
Cancel the alarm by NC reset or by turning OFF the rotary axis configuration parameter switch request
signal.
M01

Interference check invalidated

Details
The 3D machine interference check is invalidated. This alarm is output to NC alarm 5.
Remedy
Validate all the interference check settings.
If there is any axis which has not completed zero point return, establish the zero point first.
M01

Machine interference 1

Details
It was judged that an interference occurred in the No.1 step interference check and caused a deceleration stop.
When machine interference is detected, the interfered part is highlighted (yellow/red) and the part's name is
displayed on the 3D monitor's model display.
Remedy
Move the axis in a direction which does not cause interference.
Press RESET to cancel the alarm.
(In manual operation)
You can move the axis in the same travel direction as before the interference.
But the axis movement is done using the 2nd step interference check distance.
M01
Machine interference 2
Details
It was judged that an interference occurred in the No.2 step interference check and caused a deceleration stop.
When machine interference is detected, the interfered part is highlighted (red) and the part's name is displayed
on the 3D monitor's model display.
Remedy
Move the axis in a direction which doesn't cause interference.
Press RESET to cancel the alarm.
M01

Tool interfere. check disabled

Details
Tool interference check has been disabled.
This alarm is output to the NC alarm 5.
Remedy
Turn ON the [Tool check] menu of 3D monitor.
Set the tool data.
If you prevent an alarm from being output while the tool interference check is disabled, set "0" in "#11100
3D_MChk_ToolAlm".
19
0187
0200
0201
0202
0205
IB-1501279-H

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

C80 seriesM80 seriesE80 series

Table of Contents