M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
(PR)
#1493
ref_syn
0: Master axis and slave axis determine their zero points individually.
1: The zero points of both master and slave axes are determined by initializing the master axis' zero point.
The slave axis moves in perfect synchronization with the master axis.
Set this to "1" for speed/current command synchronization control.
(PR)
#1494
dsp_ax_change
Set this in order to change the axis order of counter display.
If this is set, the axes will be displayed in ascending order.
However, axis whose setting is "0" will be displayed after axes whose settings are between "1" and "16" are
displayed.
(Note 1) When the same value is set for more than one axis, axis that is displayed on the left side on the
parameter screen will be first displayed.
(Note 2) When both of the mixed control (cross axis control) and interchange coordinate position display
("1280 ext16/bit2" OFF) are valid, and when there are two or more valid part systems, this parameter will
be ignored.
(Note 3) When the arbitrary axis exchange control (option) is ON, and when there are two or more valid part
systems, this parameter will be ignored.
---Setting range---
0: The axis is displayed after the axes whose settings are between "1" and "16" are displayed.
1 to 16: Axes are displayed in ascending order.
If the number other than "1" to "16" is set, it is dealt as "0" setting.
(PR)
#1495
grf_ax_direction
[M8]
Select the axis travel direction in the 2D graphic drawing (trace, check).
If set to 1, the positive/negative directions are reversed.
---Setting range---
0/1
[C80]
Not used.
(PR)
#1496
push_typ
[C80]
0: Zero point establishing operation is determined by #1493.
1: When both the master and slave axes reach the current limit during stopper-method zero point estab-
lishment with #1493 set to 1, droop is cancelled, and the operation goes into the next step.
(PR)
#1601
axnameEx
[M8]
Specify the second letter of command axis name when the axis name extension parameter is valid "#1266
ext02/bit0 = 1".
The command axis name is not extended if this parameter is unspecified, and the only one letter set in "#1013
axname" or "#1014 incax" respectively is the absolute command axis name or incremental command axis
name.
Axis configuration should not be as the non-name extension axis (1-letter axis) after the name extension axis
(2-letter axis) in the part system.
(Configure the 2-letter axis after the 1-letter axis)
---Setting range---
A to Z (Setting is cleared when "0" is set)
[C80]
Not used.
Synchronization at zero point initialization
Axis order of counter display
Axis travel direction in 2D graphic
Stopper method in zero point establishing operation
Axis name extension letter
377
IB-1501279-H

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

C80 seriesM80 seriesE80 series