#1041
l_inch
Select the unit system for the program travel amount when the power is turned ON or reset and for position
display.
0: Metric system
1: Inch system
(Note) The units of the following data are converted by "#1041 I_inch".
- Command unit at power ON and reset (Inch/metric command mode)
But under the following conditions, the unit will follow G20/G21 command modal even at reset.
When reset modal is retained ("#1151 rstint"="0")
When G code group 06 reset modal is retained ("#1210 RstGmd/bit5" ON)
- Unit system for position display (counter, user parameter, tool, work offset)
- User parameter I/O unit
- Parameter unit of user parameters concerning length and speed
- Arc error parameter (#1084 RadErr)
#1078
Decpt2
Select the increment of position commands that do not have a decimal point.
0: Minimum input command unit (follows "#1015 cunit")
1: 1mm (or 1inch) unit (For the dwell time, 1s unit is used.)
#1080
Dril_Z
Select a fixed cycle hole drilling axis.
0: Use an axis vertical to the selected plane as hole drilling axis.
1: Use the Z axis as the hole drilling axis regardless of the selected plane.
#1091
Mpoint
Select how to handle the middle point during G28 and G30 reference position return.
0: Pass the middle point designated in the program and move to the reference position.
1: Ignore the middle point designated in the program and move straight to the reference position.
#1103
T_Life
Select whether to use the tool life management.
0: Not use
1: Use
#1104
T_Com2
Select how to handle the tool command in the program when "#1103 T_Life" is set to "1".
0: Handle the command as group No.
1: Handle the command as tool No.
(Note) In the case of the tool life management III, the program tool command will be handled as the tool No.
regardless of the setting.
#1105
T_Sel2
Select the tool selection method when "#1103 T_Life" is set to "1".
0: Select in order of registered No. from the tools used in the same group.
1: Select the tool with the longest remaining life from the tools used or unused in the same group.
#1106
Tcount
Select the input method when address N is omitted in inputting the data (G10 L3 command) for tool life man-
agement function II.
0: Time specified input
1: Number of times specified input
IB-1501279-H
Initial state (inch)
Decimal point type 2
Drilling Z fixed
Ignore middle point
Validate life management
Tool command method 2
Tool selection method 2
Life management (for L system only)