M800/M80/E80/C80 Series Alarm/Parameter Manual
12 Program Errors (P)
P273
Macro call nesting over
Details
The number of macro call nests exceeded the limit imposed by the specifications.
Remedy
Correct the program so that the macro calls do not exceed the limit imposed by the specifications.
P275
Macro argument over
Details
The number of argument sets in the macro call argument type II has exceeded the limit.
Remedy
Correct the program.
P276
Illegal G67 command
Details
A G67 command was issued though it was not during the G66 command modal.
Remedy
Correct the program.
Issue G66 command before G67 command, which is a call cancel command.
P277
Macro alarm message
Details
An alarm command has been issued in #3000.
Remedy
Refer to the operator messages on the diagnosis screen.
Refer to the instruction manual issued by the machine tool builder.
P280
Brackets [ ] nesting over
Details
Over five times have the parentheses "[" or "]" been used in a single block.
Remedy
Correct the program so that the number of "[" or "]" is five or less.
P281
Brackets [ ] not paired
Details
A single block does not have the same number of commanded parentheses "[" as that of "]".
Remedy
Correct the program so that "[" and "]" parentheses are paired up properly.
P282
Calculation impossible
Details
The arithmetic formula is incorrect.
Remedy
Correct the formula in the program.
P283
Divided by zero
Details
The denominator of the division is zero.
Remedy
Correct the program so that the denominator for division in the formula is not zero.
P288
IF EXCESS
Details
The multiplicity of the IF statement exceeded 10 times.
Remedy
The program is reviewed so that the multiplicity of the IF statement does not exceed 10 times.
IB-1501279-H