M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
#12878
aux_PSW4dog2
Set "PSW4 area setting" 1 and 2 to specify the area where the position switch 4 will turn ON when the ma-
chine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the position switch op-
eration.
For rotary axes, the output turns ON in the area excluding 0.000 degree.
---Setting range---
-99999.999 to 99999.999(° or mm)
#12879
aux_PSW5dog1
Set "PSW5 area setting" 1 and 2 to specify the area where the position switch 5 will turn ON when the ma-
chine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the position switch op-
eration.
For rotary axes, the output turns ON in the area excluding 0.000 degree.
---Setting range---
-99999.999 to 99999.999(° or mm)
#12880
aux_PSW5dog2
Set "PSW5 area setting" 1 and 2 to specify the area where the position switch 5 will turn ON when the ma-
chine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the position switch op-
eration.
For rotary axes, the output turns ON in the area excluding 0.000 degree.
---Setting range---
-99999.999 to 99999.999(° or mm)
#12881
aux_PSW6dog1
Set "PSW6 area setting" 1 and 2 to specify the area where the position switch 6 will turn ON when the ma-
chine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the position switch op-
eration.
For rotary axes, the output turns ON in the area excluding 0.000 degree.
---Setting range---
-99999.999 to 99999.999(° or mm)
#12882
aux_PSW6dog2
Set "PSW6 area setting" 1 and 2 to specify the area where the position switch 6 will turn ON when the ma-
chine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the position switch op-
eration.
For rotary axes, the output turns ON in the area excluding 0.000 degree.
---Setting range---
-99999.999 to 99999.999(° or mm)
#12883
aux_PSW7dog1
Set "PSW7 area setting" 1 and 2 to specify the area where the position switch 7 will turn ON when the ma-
chine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the position switch op-
eration.
For rotary axes, the output turns ON in the area excluding 0.000 degree.
---Setting range---
-99999.999 to 99999.999(° or mm)
IB-1501279-H
PSW4 area setting 2
PSW5 area setting 1
PSW5 area setting 2
PSW6 area setting 1
PSW6 area setting 2
PSW7 area setting 1
680