Proceed Of Prog Check Disabled; No Spec: Normal Line Control; Normal Line Control Axis G92; Normal Line Control Axis Error - Mitsubishi Electric M800 Series Manual

Hide thumbs Also See for M800 Series:
Table of Contents

Advertisement

M800/M80/E80/C80 Series Alarm/Parameter Manual
12 Program Errors (P)
P803

Proceed of prog check disabled

Details
The commanded G code has disabled the program check.
Remedy
Delete the G code that disables the program check, and then retry the program check.
(Note that deleting the G code may affect the operation of the subsequent blocks.)
P900

No spec: Normal line control

Details
A normal line control command (G40.1, G41.1, or G42.1) was issued though it is out of specifications.
Remedy
Check the specifications.
P901

Normal line control axis G92

Details
A coordinate system preset command (G92) was issued to a normal line control axis during normal line control.
Remedy
Correct the program.
P902

Normal line control axis error

Details
The normal line control axis was set to a linear axis.
The normal line control axis was set to the linear type rotary axis II axis.
The normal line control axis has not been set.
The normal line control axis is the same as the plane selection axis.
Remedy
Correct the normal line control axis setting.
P903
Plane chg in Normal line ctrl
Details
The plane selection command (G17, G18, or G19) was issued during normal line control.
Remedy
Delete the plane selection command (G17, G18, or G19) from the program of the normal line control.
P920
No spec: 3D coord conv
Details
There is no specification for 3-dimensional coordinate conversion.
Remedy
Check the specifications.
P921
Illegal G code at 3D coord
Details
The commanded G code cannot be performed during 3-dimensional coordinate conversion modal.
Remedy
Refer to the programming manual for usable G commands.
When the parameter "#8158 Init const sur spd" is enabled, disable the parameter or issue the constant
surface speed control cancel (G97) command.
P922
Illegal mode at 3D coord
Details
A 3-dimensional coordinate conversion command was issued during a modal for which 3-dimensional coordi-
nate conversion cannot be performed.
Remedy
Refer to the programming manual for usable G commands.
IB-1501279-H