Mitsubishi Electric M800 Series Manual page 631

Hide thumbs Also See for M800 Series:
Table of Contents

Advertisement

M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
#13227
SP227 SFNC7
Select the spindle functions.
Functions are allocated to each bit.
Set this in hexadecimal format.
bit F-C : dis Digital signal input selection
0: No signal
4: Proximity switch signal detection
Other settings: setting prohibited
bit B-A : dos3 Digital signal output 3 selection (MDS-EJ-SP/SP2)
bitB,A=
00: Disable
01: Setting prohibited
10: Contactor control signal output
11: Setting prohibited
bit 9-3 :
Not used. Set to "0".
bit 2 : ccu Lost motion/overshoot compensation compensation amount setting unit
0: Short-time rated %
bit 1-0 :
Not used. Set to "0".
#13228
SP228 SFNC8
Not used. Set to "0000".
IB-1501279-H
Spindle function 7
1: Short-time rated 0.01%
Spindle function 8
614
ccu
dos3
dis