16 Machine Parameters
#1541
crsax[5]
Set the axis to be interchanged during the mixed control (cross axis control).
Using two digits, set the name of the axis to be interchanged with the axis in the part system where the mixed
control (cross axis control) request signal is input, or the name of the axis to be shifted to that part system.
---Setting range---
Two digits between A to Z and 1 to 9
(Setting will be cleared when "0" is set)
#1542
crsax[6]
Set the axis to be interchanged during the mixed control (cross axis control).
Using two digits, set the name of the axis to be interchanged with the axis in the part system where the mixed
control (cross axis control) request signal is input, or the name of the axis to be shifted to that part system.
---Setting range---
Two digits between A to Z and 1 to 9
(Setting will be cleared when "0" is set)
#1543
crsax[7]
Set the axis to be interchanged during the mixed control (cross axis control).
Using two digits, set the name of the axis to be interchanged with the axis in the part system where the mixed
control (cross axis control) request signal is input, or the name of the axis to be shifted to that part system.
---Setting range---
Two digits between A to Z and 1 to 9
(Setting will be cleared when "0" is set)
#1544
crsax[8]
Set the axis to be interchanged during the mixed control (cross axis control).
Using two digits, set the name of the axis to be interchanged with the axis in the part system where the mixed
control (cross axis control) request signal is input, or the name of the axis to be shifted to that part system.
---Setting range---
Two digits between A to Z and 1 to 9
(Setting will be cleared when "0" is set)
#1558
IvOMin
Set the lower limit of the override for involute interpolation override.
---Setting range---
0 to 100 (%)
#1559
IvAMax
Set the maximum acceleration (time constant) for the acceleration clamping during involute interpolation.
---Setting range---
0 to 32767 (ms)
#1560
IvFMin
Set the minimum feedrate for the acceleration clamping during involute interpolation.
---Setting range---
0 to 999999 (mm/min)
#1561
3Dcdc
The workpiece coordinate display during 3D coordinate conversion is switched to the workpiece coordinate
system or G68 program coordinate system.
0: Workpiece coordinate system
1: G68 program coordinate system
(Note) The special display unit's absolute coordinates also follow this parameter setting.
IB-1501279-H
Involute interpolation override lower limit value
Involute interpolation allowable acceleration speed
Involute interpolation minimum feedrate
Switch workpiece coordinate display during 3D coordi-
nate conversion