M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
(PR)
#24003+40(n-1)
[M8]
Select whether to clear or hold the data input from the data link faulty station.
"n" represents the expansion slot No.(n=1 to 3)
0: Clear
1: Hold
(Note) Refer to "CC-Link System Master/Local Module User's Manual (SH(NA)-080394E)" for the details of
the functions.
---Master station---
Set to "0" or "1".
---Local/standby master station---
Set to "0" or "1".
#24004+40(n-1)
[M8]
Set whether to refresh or compulsorily clear the slave stations at PLC STOP.
"n" represents the expansion slot No.(n=1 to 3)
0: Refresh
1: Compulsorily clear
(Note) Refer to "CC-Link System Master/Local Module User's Manual (SH(NA)-080394E)" for the details of
the functions.
---Master station---
Set to "0" or "1".
---Local/standby master station---
Set to "0" or "1".
(PR)
#24005+40(n-1)
[M8]
Set the number of occupied local and standby master stations.
"n" represents the expansion slot No.(n=1 to 3)
---Master station---
Set to "0".
---Local/standby master station---
Set to either of "1" to "4".
---Setting range---
0 to 4
(PR)
#24006+40(n-1)
[M8]
Set the magnification for the extended cyclic operation of the local station whose type corresponds to Ver.2.
"n" represents the expansion slot No.(n=1 to 3)
Set "1" for the local station whose type corresponds to Ver.1.
This function is out of specifications when the protocol version is Ver.1. The setting for the local station is
fixed to "1".
---Master station---
Set to "0".
---Local/standby master station---
Set to either of "1", "2", "4" or "8".
---Setting range---
0,1,2,4,8 (fold)
SLn set fault sta
SLn PLC stop set
SLn occ stations
SLn extended cyc
661
Setting of data link faulty station
Setting at PLC STOP
Number of occupied stations
Extended cyclic setting
IB-1501279-H