M800/M80/E80/C80 Series Alarm/Parameter Manual
7 Distance-coded Reference Scale Errors (Z8*)
7Distance-coded Reference Scale Errors (Z8*)
Z80
Basic position lost
Details
The basic point data saved in the NC has been damaged.
Remedy
Set the parameters. If the basic point data is not restored by setting the parameters, perform zero point
initialization.
Z80
Basic position restore
Details
The basic point data has been restored by setting the parameters.
Remedy
Turn the power ON again to start the operation.
Z80
No spec: Distance-coded scale
Details
The distance-coded reference scale has been set available although this function is out of the specifications.
Remedy
Check the specifications.
If you do not use this function, correct the detector type with the servo parameter.
Z81
R-pos adjustment data lost
Details
Reference position adjustment value data saved in the NC has been damaged.
Remedy
Set the parameter. If the data is not restored by setting the parameter, establish the reference position
again.
Z81
R-pos adjustment data restored
Details
After the 'Z81 R-pos adjustment data lost 0001', the data has been recovered by setting the parameter.
Remedy
Establish the reference position to start the operation.
Z83
NC started during SP rotation
Details
The NC was started while the spindle was rotating.
Remedy
Turn the power OFF and confirm that the spindle is not rotating, then turn the power ON again.
You can select whether or not to stop the spindle forcibly at the occurrence of this alarm by the setting of the
base common parameter "#1284 ext20/bit1 (Spindle control selected in response to Z83 (NC started during SP
rotation))".
IB-1501279-H
0001
0002
0003
0001
0002
0001
102