1 Operation Errors (M)
M01

Move cmnd invld to synchro ax

Details
A travel command was issued to a synchronous axis in synchronous control.
Remedy
Correct the program.
M01

No spindle speed clamp

Details
When the parameter "#1146 Sclamp" has been set to "1", the constant surface speed command (G96)
was issued to the spindle which is not selected for the spindle speed clamp command (G92/G50) under
Multiple spindle control II.
When the parameter "#1146 Sclamp" has been set to "0", both the G96 (Constant surface speed control
ON) modal and the pindle forward or reverse rotation signal have turned ON for the spindle, on which the
speed clamp command is disabled.
Remedy
Press the reset key and carry out the remedy below.
Issue the G92/G50 command to the spindle that is to be used for the constant surface speed control.
M01

Cont ax superimpos II prm illg

Details
 There is a mistake in the setting of the superimposition control base axis parameter (#2089 bsax_pl).
 Superimposition control is not available under the current parameter settings.
Remedy
- Correct the parameter.
M01

Sync error btwn part systems

Details
After a single block stop or automatic operation pause was executed during single block stop operation be-
tween part systems, cycle start has not been performed on either part system.
Remedy
Perform cycle start for all the part systems where a single block stop or automatic operation pause was exe-
cuted.
M01
Z detect speed parameter error
Details
Phase-Z detection speed has not been set in "#3109 zdetspd".
Remedy
Set the phase-Z detection speed in "#3109 zdetspd".
M01
Intrf chck across sys: Set err
Details
Setting of Interference check across part systems is incorrect.
Remedy
Correct the setting of Interference check across part systems.
M01
Intrf chck across sys: Area AL
Details
Interference is already occurring on the set interfering object.
Remedy
Turn OFF the interference check valid signal, moving the axis to a position where the interfering objects
do not collide each other, and then restart Interference check across part systems.