M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
#24121+15(m-1)
[M8]
Set the type of the connected remote station, local station, intelligent device station and standby master sta-
tion.
0: No setting
1: Ver.1 remote I/O station
2: Ver.1 remote device station
3: Ver.1 intelligent device station
4: Ver.2 remote device station
5: Ver.2 intelligent device station
"m" means the m-th connected station in ascending order of station No. (m= 1 to 64)
---Master station---
Set to either of "0" to "5".
---Local/standby master station---
Set to "0".
#24122+15(m-1)
[M8]
Select the magnification for the extended cycling operation of the connected remote, local and intelligent sta-
tions.
Set "1" when the protocol version is Ver.1.
Set "0" when no setting is required.
"m" means the m-th connected station in ascending order of station No. (m=1 to 64)
---Master station---
Set a value within the setting range.
---Local/standby master station---
Set to "0".
---Setting range---
0,1,2,4,8 (times)
#24123+15(m-1)
[M8]
Set the number of the occupied stations by the connected remote, local and intelligent stations.
Set 1 for 8 points I/O and 16 points I/O.
Set "0" when no setting is required.
"m" means the m-th connected station in ascending order of station No. (m= 1 to 64)
---Master station---
Set a value within the setting range.
---Local/standby master station---
Set to "0".
---Setting range---
0 to 4 (stations occupied)
IB-1501279-H
CNm station type
CNm extended cyc
CNm occ stations
670
Station type
Extended cyclic setting
Number of occupied stations