M800/M80/E80/C80 Series Alarm/Parameter Manual
15 User Parameters
#19010
Corner check width
Corner deceleration check width
When deceleration of the currently executed block has started and a position error width between the pro-
grammed end point and machine position has reduced to this parameter or less, the control starts execution
of the next block.
N001
---Setting range---
0 to 99.999 (mm)
#19012
Ana-Tap-Voltage1
[M8]
Analog spindle synch tap: Voltage output magnification (at cutting)
Specify the spindle speed magnification to be applied during cutting in analog spindle synchronous tapping.
When 0 is set, the magnification is taken as 100%.
If the spindle fails to rotate as commanded due to such as cutting load, set this parameter to correct the
speed.
---Setting range---
0 to 200 (%)
#19013
Ana-Tap-Voltage2
[M8]
Analog spindle synch tap: Voltage output magnification (at retract)
Specify the spindle speed magnification to be applied during retract in analog spindle synchronous tapping.
When 0 is set, the magnification is taken as 100%.
If the spindle fails to rotate as commanded due to such as cutting load, set this parameter to correct the
speed.
---Setting range---
0 to 200 (%)
#19101
Stylus sphere dia.
[M8]
Specify the diameter of stylus sphere that is used for measurement of rotation center error or workpiece in-
stallation error.
If the set value is significantly different from the actual diameter, the sensor may be damaged.
---Setting range---
0.000, 0.100 to 10.000 (mm)
#19102
Stylus length
[M8]
Specify the length of stylus that is used for workpiece installation error measurement.
If the set value is significantly different from the actual length, the sensor may be damaged.
---Setting range---
0.000 to 99999.999 (mm)
IB-1501279-H
N002
Machine position
214